![]() This saves time and prevents operation errors. You can switch between the two modes with just one mouse click – no need to exchange the hardware, re-validate or re-align sensitive optics. The instrumental implementation of static light scattering in a measuring device is shown in the Figure. ![]() Comparison of particle sizing methods: Laser diffraction vs. The PSA series: Measurement of liquid and dry samples with just one instrument PSA instruments are the only particle size analyzers that can be configured with fully integrated liquid and dry dispersion modes in one instrument. This article describes the principal differences between dynamic light scattering and laser diffraction, and it also provides an overview of the options for data interpretation and possible comparison. Therefore, a significant fraction of very small. POLARIZATION X and y ray production by template modulated coherent light II. The Litesizer series: Two instruments, up to five modes Besides the determination of particle size, the Litesizer™ particle analyzers also offer other analysis options such as the determination of zeta potential, molecular mass, transmittance, and refractive index. Dynamic light scattering can be used with samples that have much smaller particle sizes than laser diffraction. PERFORMANCE Continued studies of x - ray generation by laser beams. ![]() Historically, the early laser diffraction instruments only used scattering at small angles. Moreover, with Litesizer 500 you can also determine zeta potential, molecular mass, transmittance, and the refractive index for a better understanding of your sample’s stability. The laser light diffraction technique used for the determination of particlesize distribution is based on the analysis of the diffraction pattern produced when particles are exposed to a beam of monochromatic light. Instrument 4 (LD 6) uses red (632.8 nm) and blue (470 nm) LD. DLS and the Litesizer devices provide analysis in liquid dispersions only but reach down to the nanometer range. For example, Instrument 2 (LD 4) uses a red laser (750 nm or 780 nm) as well as a tungsten-halogen light source for the polarization intensity differential scattering (450 nm, 600 nm, and 900 nm) to provide the dynamic range analysis. LD and the PSA instruments are used for analyzing particles ranging up to the millimeter sizes in liquid or dry dispersions. Depending on the size of particles and whether you are measuring your sample in liquid or dry dispersion, either laser diffraction (LD) or dynamic light scattering (DLS) is the technique of choice. In particle size measurements using dynamic light scattering (DLS), a laser beam is scattered on very small, finely dispersed particles (usually < 1 m) in a. Particle size analysis over an extensive range The Litesizer and PSA series together cover the measurement of particle sizes from the lower nanometer to the millimeter range using different techniques. Laser diffraction analysis, also known as laser diffraction spectroscopy, is a technology that utilizes diffraction patterns of a laser beam passed through any object ranging from nanometers to millimeters in size to quickly measure geometrical dimensions of a particle. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |